Safekipedia

Cryogenics

Discoverer · ages 10+Adapted from Wikipedia
Liquid nitrogen is extremely cold, about -196°C (-321°F), and it boils into a gas as soon as it warms up.

In physics, cryogenics is the production and behaviour of materials at very low temperatures. Some other pages share similar names. The journal Low Temperature Physics (journal), the song Cryogen (song), and the band Cryogenic (band) are covered on their own pages. For the freezing and preserving of humans, see Cryonics.

Nitrogen is a liquid under −195.8 °C (77.3 K).

In 1971, the 13th International Institute of Refrigeration's (IIR) International Congress of Refrigeration, held in Washington, DC, agreed on a shared meaning for "cryogenics" and "cryogenic." They set the dividing line at 120 K (−153.15 °C). This line separates these terms from ordinary refrigeration. It makes sense because the normal boiling points of the so-called permanent gases, such as helium, hydrogen, neon, nitrogen, oxygen, and normal air, are below 120 K. The Freon refrigerants, hydrocarbons, and other common refrigerants have boiling points above 120 K.

Scientists have become interested in superconducting materials that work at temperatures well above the boiling point of nitrogen. This has created interest in reliable, low-cost ways to make high-temperature cryogenic refrigeration. The first discovery of superconductivity is credited to Heike Kamerlingh Onnes on 10 July 1908, after they reached a temperature of 2 K. These first superconducting properties were seen in mercury at 4.2 K.

Cryogenicists measure temperature using the Kelvin or Rankine scales. Both start from absolute zero. Many people use other scales, such as Celsius, which starts from the freezing point of water at sea level, or Fahrenheit, which starts from the freezing point of a particular brine solution at sea level.

Definitions and distinctions

Cryogenics is the branch of engineering that studies very low temperatures (below 123 K), how to produce them, and how materials behave at those temperatures. Cryobiology is the branch of biology that studies the effects of low temperatures on organisms, most often to achieve cryopreservation. It also includes freeze-drying of pharmaceutical components and medicine. Cryoconservation of animal genetic resources means keeping genetic material to preserve a breed, and this is not limited to animals. Many services store genetic material or preserve stem cells at birth, which may be used to study cell lines or for stem-cell therapy. Cryosurgery uses cryogenic temperatures to destroy tissue, such as cancer cells, and is commonly called cryoablation.

Cryoelectronics is the study of electronic effects at cryogenic temperatures, including superconductivity and variable-range hopping. Cryonics is the cryopreserving of humans and animals with the intention of future revival. "Cryogenics" is sometimes wrongly used to mean "cryonics" in popular culture and the press.

Etymology

The word cryogenics comes from Greek. It joins κρύος (cryos), meaning "cold," and γενής (genis), meaning "generating."

Cryogenic fluids

This is a diagram of an infrared space telescope that needs a cold mirror and instruments. One instrument needs to be even colder, and it has a cryocooler. The instrument is in region 1 and its cryocooler is in region 3 in a warmer region of the spacecraft (see MIRI (Mid-Infrared Instrument) or James Webb Space Telescope).

Cryogenic fluids with their boiling point in Kelvin and degree Celsius.

FluidBoiling point (K)Boiling point (°C)
Helium-33.19−269.96
Helium-44.214−268.936
Hydrogen20.27−252.88
Neon27.09−246.06
Nitrogen77.09−196.06
Air78.8−194.35
Fluorine85.24−187.91
Argon87.24−185.91
Oxygen90.18−182.97
Methane111.7−161.45
Krypton119.93−153.415

Industrial applications

A medium-sized dewar is being filled with liquid nitrogen by a larger cryogenic storage tank.

Further information: Low-temperature technology timeline

Liquefied gases, such as liquid nitrogen and liquid helium, are used in many cryogenic applications. Liquid nitrogen is the most commonly used element in cryogenics and can be bought legally around the world. Liquid helium is also common and allows the lowest attainable temperatures to be reached. These liquids are often kept in Dewar flasks, which have two walls with a high vacuum between them. They are named after James Dewar, who first liquefied hydrogen. Smaller Thermos bottles are vacuum flasks in a protective casing. Cryogenic pumps and valves move liquefied natural gas at LNG piers from LNG carriers to LNG storage tanks. The commercial cryogenic processing industry was founded in 1966 by Bill and Ed Busch, who started a company in Detroit called CryoTech. It was based on the idea of cryogenic hardening, which came from the finding that frozen metals resisted wear better. Busch first tested cryogenic tempering to make metal tools last longer, which later grew into treating other parts.

Cryogenic processing is not a replacement for heat treating, but an extra step after it. Cryogens such as liquid nitrogen are also used for chilling and freezing. Some chemical reactions for statin drugs must happen at very low temperatures, so special chemical reactors are used. Nitrogen also helps freeze foods and products like vaccines. Some materials become brittle when very cold, which makes cryomilling useful. Cryogenics is also used in cryogenic fuels for rockets, with liquid hydrogen the most widely used and liquid methane becoming more common. Liquid oxygen is used as an oxidizer rather than a fuel. NASA's Space Shuttle used cryogenic hydrogen and oxygen to reach orbit. Liquid oxygen is also used with RP-1 kerosene in rockets built for the Soviet space program by Sergei Korolev. The Russian company Tupolev made a version of its Tu-154 plane with a cryogenic fuel system, called the Tu-155, which made its first flight in 1989.

Other applications

Astronomical instruments on the Very Large Telescope are equipped with continuous-flow cooling systems.

Cryogenics helps with many science and health tools. Nuclear magnetic resonance (NMR) is a common way to learn about the physical and chemical properties of atoms. Its strong magnetic fields are made by supercooled electromagnets, and liquid helium is often used to cool them. Magnetic resonance imaging (MRI) uses NMR to create images of objects, and it is most often used in health care. Cryogenic electron microscopy (cryoEM) is a popular method in structural biology for studying the shapes of proteins, cells, and other living systems. Samples are frozen in liquid ethane, cooled by liquid nitrogen, and then viewed in an electron microscope, which is also cooled by liquid nitrogen. Cold can also help move electricity. Underground cables in large cities can lose power as they heat up, and superconductors cooled with liquid nitrogen or helium could help transmit power more efficiently. This idea is the subject of an agreement within the International Energy Agency.

Cryogenic gases are also used to transport and store large amounts of frozen food for long periods, which is useful when food must reach war zones or areas hit by earthquakes. Many forward looking infrared cameras need their detectors cooled this way. Some rare blood groups are kept at very low temperatures, such as −165 °C, in blood banks. Systems using liquid nitrogen and CO2 create a chilly effect and white fog for nightclub lighting. In manufacturing processes, cooling the tool tip during machining makes the tool last longer. Freezing a tire in liquid nitrogen makes the rubber brittle, so it can be crushed into particles that can be reused. Research on spintronics also needs cryogenic temperatures to see certain effects. Some vaccines, such as the Pfizer–BioNTech COVID-19 vaccine, must be stored between −90 and −60 °C. (See cold chain.)

Production

Cooling devices and materials to very low temperatures is usually done with liquid nitrogen, liquid helium, or a mechanical cryocooler, which uses high-pressure helium lines. Gifford-McMahon cryocoolers, pulse tube cryocoolers and Stirling cryocoolers are widely used. The choice depends on the lowest temperature needed and how much cooling is required.

The newest development in cryogenics is the use of magnets as regenerators and refrigerators. These devices work on a principle called the magnetocaloric effect.

Detectors

Scientists use various cryogenic detectors to find particles.

To measure very cold temperatures down to 30 K, they use Pt100 sensors, which are a resistance temperature detector (RTD). For temperatures below 30 K, a silicon diode is needed to measure accurately.

Quiz time!

5 questions about Cryogenics

Question 1 of 5

What does cryogenics mainly study in physics?

Pictures

Valves used with liquid nitrogen, coated in a thick layer of frost.
A cryogenic gases delivery truck parked at a Kroger supermarket in Ypsilanti, Michigan.
A cryogenic carbon steel globe valve with socket weld ends, the kind of metal valve used to control the flow of liquids and gases in industrial pipes.

Keep exploring

This article is a child-friendly adaptation of the Wikipedia article on Cryogenics, available under CC BY-SA 4.0.

Images from Wikimedia Commons. Tap any image to view credits and license.